FAQ within [ Drive Products ]
-
Setting a smaller value in Pr.1106 (Torque monitor filter) improves the response because the filter time constant for the torque monitoring becomes smaller, ... More Details >>
- No:21045
- Release Date:2018/08/22 16:25
- Category: Inverters-FREQROL
-
The number of timer points is 16 for the high speed and low speed in total. More Details >>
- No:21056
- Release Date:2018/08/22 16:25
- Category: FREQROL-A800 , FREQROL-F800
-
For the FR-F800 series, in addition to the conventional Optimum excitation control, Advanced optimum excitation control with the improved starting torque is ... More Details >>
- No:21072
- Release Date:2018/08/22 16:25
- Category: Inverters-FREQROL , FREQROL-F800
-
Configure the same setting as the SF-HRCA. Configure the same setting as the SF-HRCA. A700, E700, D700, F700PJ: Pr.71 = 50F700P, F700: Pr.71 = 1 (Reference) ... More Details >>
- No:21136
- Release Date:2018/08/22 16:26
- Category: Inverters-FREQROL , FREQROL-E700 , FREQROL-D700 , Peripheral devices , FREQROL-A700 , FREQROL-F700 , FREQROL-F700P , FREQROL-F700PJ
-
It is one of other communication errors. The communication is not established. Check the communication settings. More Details >>
- No:21176
- Release Date:2018/08/22 16:26
- Category: Inverters-FREQROL , Engineering Software
-
Switching between External operation mode and PU operation mode
Assign X16 signal, and set Pr.79 to "0", to switch the operation mode with turning ON/OFF X16 signal. More Details >>
- No:21288
- Release Date:2018/08/22 16:26
- Category: Inverters-FREQROL , FREQROL-E700 , FREQROL-D700 , FREQROL-A700 , FREQROL-F700 , FREQROL-F700P , FREQROL-F700PJ
-
Normally, the inverter starts up in the NET operation mode at power ON when Pr.340 is set to "10" and Pr.79 is set to "0". When it starts up in the PU operat... More Details >>
- No:21319
- Release Date:2018/08/22 16:27
- Category: Inverters-FREQROL , FREQROL-E700 , FREQROL-D700 , FREQROL-A700 , FREQROL-F700 , FREQROL-F700P , FREQROL-F700PJ
-
Check the setting value of Pr.73. Or check Pr.C4 (Terminal 2 frequency setting gain) for the percentage of the voltage that is actually applied. For the FR-E... More Details >>
- No:21356
- Release Date:2018/08/22 16:27
- Category: FREQROL-E700
-
Wire length between inverter and motor
1. Wiring length between the inverter and the motor should be 500 m or less. For 0.75 kW or lower motors, the following relationship is true: Capacity... More Details >>
- No:21392
- Release Date:2018/08/22 16:27
- Category: Inverters-FREQROL
-
Countermeasure against noise and leakage current during low-noise operation
The following two major countermeasures against noise are available: - Keep the noise source and partner device apart from each other.- Install a noise filte... More Details >>
- No:21605
- Release Date:2018/08/22 16:28
- Category: Inverters-FREQROL , FREQROL-A024